ASTMA518-99 (2012) |
BS 1591 1975 |
||
Grade 1 (Si-Fe) |
Grade 3 (Si-Fe-Cr) |
||
Carbon |
0.65~1.10% |
0.70~1.10% |
1.40% Max. |
Manganese |
1.50% Max. |
1.50% Max. |
0.50% Max. |
Silicon |
14.20~14.75% |
14.20~14.75% |
14.25~15.25% |
Chromium |
0.50% Max. |
3.25~5.00% |
0.50% Max. |
Molybdenum |
0.50% Max. |
0.20% Max. |
~~ |
Copper |
0.50% Max. |
0.50% Max. |
~~ |
Sulphur |
~~ |
~~ |
0.10% Max. |
Phosphorus |
~~ |
~~ |
0.25% Max. |
Iron |
Remainder |
Remainder |
Remainder |
Environment |
Nominal Current Density |
Consumption Rate |
Note |
Soil / Fresh Water |
2-5 A/m2 |
0.1-0.5 kg/A-y |
Avoid: Dry Soils High Sulfate Consider during design: End Effect Brittle Chrome Alloy-Chloride Environment |
0.2-0.5 A/ft2 |
0.2-1.2 Ibs/A-y |
||
Carbon Backfill |
5.0-10 A/m2 |
0.05-0.3 kg/A-y |
|
0.5-1.0 A/ft2 |
0.1-0.7 Ibs/A-y |
||
Seawater |
10-50 A/m2 |
0.3-0.5 kg/A-y |
|
1.0-5.0 A/ft2 |
0.7-1.0 Ibs/A-y |
Testing |
Chemical Composition |
PhysicalAppearance |
Standards & Methods |
ISO 9001:2015 Quality Management System and Foundry Internal Standards of HSCI Tubular Anodes |
|
ASTM E350 |
ASTM E186/E446,Foundry ITP |
|
Testing Items |
Chemical Analysis |
Anode Surface, Finish and Appearance (Oxide Slag, Internal Shrinkage, Gas Porosity, Surface Crack, Non-metallic Inclusion etc.) Anode Size, Unit Weight Lead Wire / Cable Specification, Pulling Tension of Lead Wire / Cable connection Epoxy Resin Sealing,Connection Resistance,Drop Impact test etc. |
Equipment & Devices |
Optical Emission Spectrometer Labspark 750A, Thermoscientific Niton XL2-980
|
Calibrated Digital Measuring Devices
|
Jennings Anodes casting process ensures the ultimate performance of the anode and the life of the anode. Our internal testing standards and the 3rd party tests are performed to guarantee high quality of the products. Every anode is stamped with a unique serial number for quality tracking and after-sale service.
According to ASTM sampling practice, anode samples are taken before and after every heat. Quality Assurance and Quality Control procedures are employed and strictly implemented to guarantee the performance of Jennings Anodes products.
Testing reports are enclosed in the shipping documents for each order. The 3rd party testing is conducted by customer’s special request at extra charge.
Jennings Anodes has strict packing standards to guarantee safe delivery. Clear shipping marks and documentation make it easier for acceptance of the order.
Anode Model |
Unit of Measurement |
Packing Details |
||||
Number of Anodes per Crate/Pallet
|
Crate/Pallet Dimension |
Net Weight |
Gross Weight |
Number of Crates/ Pallets per 20ft. Container |
||
JA-48-SA2S |
EA |
90 |
57” × 24” × 29” (1450 × 600 × 730mm) |
2083Ibs (945kg) |
2194Ibs (995kg) |
22 |
JA-48-SA3S |
56 |
57” × 23” × 28” (1450 × 590 × 720mm) |
2222Ibs (1008kg) |
2359Ibs (1070kg) |
20 |
|
JA-48-SA4S |
25 |
57” × 24” × 27” (1450 × 600 × 690mm) |
2205Ibs (1000kg) |
2348Ibs (1065kg) |
20 |
Custom packing is available upon request.
Shipping Documents
1. Proforma Invoice
2. Packing List
3. Testing Reports (Chemical Composition, Electrochemical Properties Test, Certificate of Compliance)